    PACIFIC INSULATING MATERIAL CO LTD E115974
    2ND FL, BLK A
    MERIT INDUSTRIAL CENTER
    94 TOKWANWAN RD
    KOWLOON, HONG KONG

    Industrial laminates:

    Build up R.T.I. H

    Mtl
    Dsg

    ANSI
    Type


    Color
    Min
    Thk
    (mm)

    Flame
    Class

    Elec
    (°C)

    Mech
    (°C)
    H
    W
    I
    H
    A
    I
    V
    T
    R
    C
    T
    I
    Meets
    746E
    DSR

    Industrial laminates, furnished as sheets.

    FL-150 FR-4 NC 0.38 V-0 130 130 0 1 - - Yes
    0.63 V-0 130 140 0 1 - - Yes
    1.40 V-0 130 140 0 1 - 3 Yes

    Industrial laminates, furnished as sheets or rolls.

    FL-170 FR-4 NC 0.38 V-0 130 130 1 1 - - Yes
    0.63 V-0 130 140 0 1 - - Yes
    1.40 V-0 130 140 0 1 - 4 Yes

    Industrial laminates, furnished as sheets, rods or tubes.

    DF-150 FR-4 YL 0.38 V-0 130 130 0 0 - - -
    0.64 V-0 130 140 0 3 4 - Yes
    1.40 V-0 130 140 0 2 4 4 Yes
    DF-170 FR-4 NC 1.40 V-0 130 140 0 2 - 4 Yes
    0.63 V-0 130 140 0 3 - - Yes
    0.38 V-0 130 130 0 3 - - Yes
    DF-170A FR-4 NC 0.38 V-0 130 130 0 0 - - -
    0.64 V-0 130 140 0 0 - - -
    1.40 V-0 130 140 0 0 - 4 -
    FL-140 FR-4 NC 1.40 V-0 130 140 0 2 - 4 Yes
    0.63 V-0 130 140 0 3 - - Yes
    0.38 V-0 130 130 0 1 - - Yes
    FL-150f No ANSI NC 0.38 V-0 - - - - - - -
    0.63 V-0 - - - - - - -
    1.40 V-0 - - - - - - -
    FL-170f No ANSI NC 0.38 V-0 - - - - - - -
    0.63 V-0 - - - - - - -
    1.40 V-0 - - - - - - -
    HF-140 FR-4 NC 0.38 V-0 130 130 0 2 - - Yes
    0.63 V-0 130 140 0 2 - - Yes
    1.40 V-0 130 140 0 2 - 3 Yes
    HF-170 FR-4 NC 0.38 V-0 130 130 0 3 - - Yes
    0.63 V-0 130 140 0 3 - - Yes
    1.40 V-0 130 140 0 2 - 3 Yes
    P-110 FR-1 NC 0.71 V-0 130 130 3 3 0 3 -
    1.45 V-0 130 130 3 3 0 3 -
    P-112 FR-2 NC 0.71 V-0 75 75 4 3 1 4 -
    1.45 V-0 105 105 4 3 1 4 -
    P-121 CEM-1 NC, PK 0.63 V-0 130 140 3 2 1 - -
    1.64 V-0 130 140 1 2 3 3 -
    P-123 CEM-3 NC 0.63 V-0 130 140 0 2 1 - -
    1.40 V-0 130 140 0 2 1 0 -
    P-123T CEM-3 TP 0.63 V-0 130 140 0 2 1 - -
    1.40 V-0 130 140 0 2 1 3 -
    P-127 CEM-3 WT 0.63 V-0 130 140 0 2 1 - -
    1.40 V-0 130 140 0 2 1 3 -
    P-138 FR-4 YL 0.38 V-0 130 130 0 0 - - -
    0.64 V-0 130 140 0 0 - - -
    1.40 V-0 130 140 0 0 2 3 -
    P-138H FR-4 YL 0.38 V-0 130 130 0 0 - - -
    0.64 V-0 130 140 0 0 - - -
    1.40 V-0 130 140 0 0 2 3 -
    P-138T No ANSI NC 0.38 V-0 50 50 - - - - -

    Ultrathin build ups:

    Build Up Laminate Prepreg
    Mtl
    Dsg
    ANSI
    Type
    Min Thk
    (mm)
    TI
    Elec
    TI
    Mech
    Mtl
    Dsg
    Thk
    (mic)
    TI
    Elec
    Mtl
    Dsg
    Thk
    (mic)
    TI
    Elec

    Ultrathin industrial laminates and bonding layers, furnished in sheet form, for use in multilayer printed wiring boards where the thickness is built up to the minimum specified.

    DF-150 FR-4 0.38 130 130 DF-150 70 90 PP-DF150 50 90
    DF-170 FR-4 0.38 130 130 DF-170 60 90 PP-DF-170 50 90
    DF-170A FR-4 0.38 130 130 DF-170A 50 90 PP-DF170A 50 90
    FL-140 FR-4 0.38 130 130 FL-140 60 90 PP-FL140 50 90
    FL-150 FR-4 0.38 130 130 FL-150 50 90 PP-FL150 50 90
    0.45 130 130 FL-150 50 90 PP-FL150 50 90
    0.63 130 140 FL-150 50 90 PP-FL150 50 90
    1.40 130 140 FL-150 50 90 PP-FL150 50 90
    FL-150f No ANSI 0.38 - - FL-150f 50 - PP-FL150f 50 -
    FL-170 FR-4 0.38 130 130 FL-170 50 90 PP-FL170 50 90
    0.45 130 130 FL-170 50 90 PP-FL170 50 90
    0.63 130 140 FL-170 50 90 PP-FL170 50 90
    1.40 130 140 FL-170 50 90 PP-FL170 50 90
    FL-170f No ANSI 0.38 - - FL-170f 50 - PP-FL170f 50 -
    HF-140 FR-4 0.38 130 130 HF-140 50 90 PP-HF140 50 90
    HF-170/PP-HF170 FR-4 0.38 130 130 HF-170 65 90 PP-HF170 50 90
    P-138 FR-4 0.38 130 130 P-138 100 120 PP-138 50 90
    P-138H FR-4 0.38 130 130 P-138H 100 120 PP-138H 50 90

    Metal clad industrial laminates:


    Bld up
    Clad Cond Thk Max Max Solder Lts
    Metal
    Clad
    Dsg
    Lam-
    inate
    Dsg
    Pre-
    preg
    Dsg

    ANSI
    Type
    Min
    Thk
    (mm)
    Min
    Ext
    (mic)
    Max
    Ext
    (mic)
    Max
    Int
    (mic)
    Area
    Dia
    (mm)

    Flame
    Class
    Oper
    Temp
    (°C)

    Temp
    (°C)

    Time
    (sec)

    Metal clad industrial laminates for use in multilayer printed wiring boards with copper on one or both sides, furnished as sheets.

    DF-150
    DF-150 PP-DF150 FR-4 0.38 12 102 - 50.8 V-0 130 288 30
    DF-170A
    DF-170A PP-DF170A FR-4 0.38 12 102 - 50.8 V-0 50 288 30
    0.56 12 102 - 50.8 V-0 130 288 30
    FL-150
    FL-150 PP-FL150 FR-4 0.38 9 102 68 50.8 V-0 130 288 30
    0.45 12 102 102 50.8 V-0 130 288 30
    FL-170
    FL-170 PP-FL170 FR-4 0.38 9 102 68 50.8 V-0 130 288 30
    0.45 9 102 102 50.8 V-0 130 288 30
    HF-140
    HF-140 PP-HF140 FR-4 0.38 12 102 102 50.8 V-0 130 288 30
    P-138 P-138 PP-138 FR-4 0.63 12 102 - 50.8 V-0 130 288 30
    P-138H
    P-138H PP-138H FR-4 0.63 12 102 - 50.8 V-0 130 288 30

    Metal clad industrial laminates for use in multilayer printed wiring boards with copper on one or both sides, furnished as sheets, rods or tubes.

    HF-170/PP-HF170
    HF-170 PP-HF170 FR-4 0.50 12 102 102 50.8 V-0 130 288 30

    Metal clad industrial laminates for use in multilayer printed wiring boards with copper on one or both sides.

    DF-170, FL-140
    DF-170 PP-DF170 FR-4 0.38 12 102 102 50.8 V-0 130 288 30

    Metal clad industrial laminates for use in single layer printed wiring boards with copper on one or both sides, furnished as sheets.

    DF-150
    DF-150 - FR-4 0.38 12 102 - 50.8 V-0 130 288 30
    DF-170A
    DF-170A - FR-4 0.38 12 102 - 50.8 V-0 50 288 30
    0.56 12 102 - 50.8 V-0 130 288 30
    FL-150
    FL-150 - FR-4 0.38 9 102 - 50.8 V-0 130 288 30
    FL-170
    FL-170 - FR-4 0.38 9 102 - 50.8 V-0 130 288 30
    HF-140
    HF-140 - FR-4 0.38 12 102 - 50.8 V-0 130 288 30
    P-121 P-121 - CEM-1 0.63 17 102 - 25.4 V-0 130 288 20
    P-123 P-123 - CEM-3 0.63 17 102 - 50.8 V-0 105 260 20
    0.63 17 102 - 25.4 V-0 130 260 20
    P-123T
    P-123T - CEM-3 0.63 17 102 - 50.8 V-0 105 260 20
    0.63 17 102 - 25.4 V-0 130 260 20
    P-127 P-127 - CEM-3 0.63 17 102 - 50.8 V-0 105 260 20
    0.63 17 102 - 25.4 V-0 130 260 20
    P-138 P-138 - FR-4 0.63 12 102 - 50.8 V-0 130 288 30
    P-138H
    P-138H - FR-4 0.63 12 102 - 50.8 V-0 130 288 30

    Metal clad industrial laminates for use in single layer printed wiring boards with copper on one or both sides, furnished as sheets, rods or tubes.

    HF-170
    HF-170 - FR-4 0.50 12 102 - 50.8 V-0 130 288 30

    Metal clad industrial laminates for use in single layer printed wiring boards with copper on one or both sides.

    DF-170, FL-140
    DF-170 - FR-4 0.38 12 102 - 50.8 V-0 130 288 30

    Metal clad industrial laminates for use in single layer printed wiring boards with copper on one side only, furnished as sheets.

    P-110 P-110 - FR-1 1.45 34 102 - 50.8 V-0 105 260 10
    P-112 P-112 - FR-2 1.45 34 102 - 50.8 V-0 105 260 10
    P-121 P-121 - CEM-1 0.63 17 102 - 50.8 V-0 130 288 20
    P-123 P-123 - CEM-3 0.63 17 102 - 50.8 V-0 130 260 20
    P-123T
    P-123T - CEM-3 0.63 17 102 - 50.8 V-0 130 260 20
    P-127 P-127 - CEM-3 0.63 17 102 - 50.8 V-0 130 260 20
    P-138 P-138 - FR-4 0.63 12 102 - 50.8 V-0 130 288 30
    P-138H
    P-138H - FR-4 0.63 12 102 - 50.8 V-0 130 288 30

    Metal clad industrial laminates (Flammability Only Recognition):


    Bld up
    Clad Cond Thk Max Max Solder Lts
    Metal
    Clad
    Dsg
    Lam-
    inate
    Dsg
    Pre-
    preg
    Dsg

    ANSI
    Type
    Min
    Thk
    (mm)
    Min
    Ext
    (mic)
    Max
    Ext
    (mic)
    Max
    Int
    (mic)
    Area
    Dia
    (mm)

    Flame
    Class
    Oper
    Temp
    (°C)

    Temp
    (°C)

    Time
    (sec)

    Metal clad industrial laminates for use in multilayer printed wiring boards with copper on one or both sides (Flammability Only Recognition).

    FL-150f
    FL-150f PP-FL150f No ANSI 0.38 - - - - V-0 - 288 30
    FL-170f
    FL-170f PP-FL170f No ANSI 0.38 - - - - V-0 - 288 30

    Metal clad industrial laminates for use in single layer printed wiring boards with copper on one or both sides, furnished as sheets (Flammability Only Recognition).

    P-138T
    P-138T - No ANSI 0.63 - - - - V-0 - 288 30

    Metal clad industrial laminates for use in single layer printed wiring boards with copper on one or both sides (Flammability Only Recognition).

    FL-150f
    FL-150f - No ANSI 0.38 - - - - V-0 - 288 30
    FL-170f
    FL-170f - No ANSI 0.38 - - - - V-0 - 288 30


    Marking: Company name or tradename "PI" , "PIC" and material designation on container or wrapper.
    Last Updated on 2011-06-06
    QMTS2.E115974 E115974 QMTS2 224 215 NO NO Engineering Request 208 230 100057507 SUZ BasicUS Listing Active listing revised YES 20110606 20110606 secure text/sgml AutoUpdt AutoUpdt 216 217 218 219 16747 Poole 16747 Poole NO NO

    Questions?

    Print this page

    Notice of Disclaimer

    Page Top

    The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service. Always look for the Mark on the product.

    UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright © 2011 Underwriters Laboratories Inc.®"

    2018天天拍拍天天爽视频